COPPER MOUNTAIN TECHNOLOGIES S7530 CALIBRATION and COPPER MOUNTAIN TECHNOLOGIES S7530 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the COPPER MOUNTAIN TECHNOLOGIES S7530 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Network Analyzer, SNA, VNA?
Shop for Comparable Products on our
 used Network Analyzer, SNA, VNA page or new Network Analyzer, SNA, VNA page

 
   COPPER MOUNTAIN TECHNOLOGIES S7530   Description / Specification:    
COPPER MOUNTAIN TECHNOLOGIES S7530 3 GHz USB S-parameter Vector Network Analyzer

The Copper Mountain S7530 VNA is a 3 GHz, 75 ohm S-parameter vector network analyzer designed for operation with an external PC. It connects to any Windows-based computer via USB and delivers accurate testing and measurement through a platform that can keep up with constant advancements as well as be remotely accessed.
Specifications.

Measured parameters: S11, S21, S12, S22.

Measurement Range.
Impedance: 75 Ω.
Test port connector: N-type, female:
Number of test ports: 2.
Frequency range: 20 kHz to 3.0 GHz.
Full CW frequency accuracy: ±5x10 -6.
Frequency setting resolution: 10 Hz.
Number of measurement points: 1 to 200,001.
Measurement bandwidth: 10 Hz to 30 kHz (with 1/1.5/2/3/5/7 steps).
Dynamic range (IF bandwidth 10 Hz):
  From 20 kHz to 300 kHz: 100 dB, typ. 110 dB,
  From 300 kHz to 3.0 GHz: 120 dB, typ. 123 dB.

Measurement Accuracy.
Accuracy of transmission measurements (magnitude / phase):
  +5 dB to +10 dB (0.2 dB / 2°),
  -50 dB to +5 dB (0.1 dB / 1°).
Accuracy of reflection measurements (magnitude / phase):
  -15 dB to 0 dB (0.4 dB / 3°),
  -25 dB to -15 dB (1.0 dB / 6°),
  -35 dB to -25 dB (3.0 dB / 20°).

Test Port Output.
Match (without system error correction): 22 dB.
Power range: 100 kHz to 6.0 GHz: -50 dBm to +5 dBm (-1 dBmV to 54 dBmV).
Power accuracy: ±1.0 dB.
Power resolution: 0.05 dB.
Harmonics distortion: -25 dBc.
Non-harmonic spurious: -30 dBc.

Test Port Intput.
Match (without system error correction): 22 dB.
Damage level: +23 dBm (71 dBmV).
Damage DC voltage: 35 V.
Noise level (defined as the rms value of the specified noise floor, IF bandwidth 10 Hz)
From 20 kHz to 300 kHz: -95 dBm.
From 300 kHz to 3.0 GHz: -115 dBm.

Measurement Speed.
Measurement time per point: 200 μs.
Source to receiver port switchover time: 10 ms.



 

Standard Calibration $730.00 *
*This is a Web introductory price for one calibration of the COPPER MOUNTAIN TECHNOLOGIES S7530. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related RF Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Average Power
Average power means that the energy transfer rate is to be averaged over many periods of the lowest frequency involved. For a CW signal, the lowest frequency and highest frequency are the same, so average power and power are the same. For an amplitude modulated wave, the power must be averaged over many periods of the modulation component of the signal as well.

Harmonic
A harmonic of a wave is a component frequency of the signal that is an integer multiple of the fundamental frequency, i.e. if the fundamental frequency is f, the harmonics have frequencies 2f, 3f, 4f, . . . etc.

Phase Noise
Phase noise is the frequency domain representation of rapid, short-term, random fluctuations in the phase of a waveform, caused by time domain instabilities. Phase noise (L(f)) is typically expressed in units of dBc/Hz, representing the noise power relative to the carrier contained in a 1 Hz bandwidth centered at a certain offsets from the carrier.


Please contact us for your COPPER MOUNTAIN TECHNOLOGIES S7530 CALIBRATION and/or COPPER MOUNTAIN TECHNOLOGIES S7530 3 GHz USB S-parameter Vector Network Analyzer REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: